We often get questions from growers about the correct application rates of Hay Guard when baling small squares. Sometimes we hear stories of people watering down Hay Guard as a solution - DO NOT DO THIS.
To make things simple, we’ve put together a helpful guide and a downloadable pdf. that help you calculate the correct flow rate.
Calculation of Nozzle Flow Rates for Small Square Balers
1. Strokes per minute divided by flakes per bale = number of bales per minute
2. Multiply bales per minute X 60 to get bales per hour
3. Multiply bales per hour X average bale weight to get tons per hour
4. Multiply tons/hr X dose rate per ton (0.8 for HayGuard) to give litres per hour
5. Divide litres/hr by 60 to give litres per minute
Example:
90 strokes/min at 12 flakes per bale = 7.5 bales/min
7.5 X 60 = 450 bales/hr
450 X 25Kg = 11.25 tons per hr
11.25 tons X 0.8 (HayGuard dose rate) = 9 Litres/hr
9L/hr divided by 60 minutes = 150mL/minute